Understanding a few basic electrical terms will help you make informed decisions during your purchase and assist you when communicating with your electrician.
- Volts: Volts measure electrical potential, representing the pressure that pushes electricity through a circuit. In Australia, standard residential electricity is delivered at a nominal voltage of 230 to 240 volts.
- Amps: Amps, short for amperes, measure electrical current, representing the volume or rate of flow. Most standard Australian household power points are rated for 10 amps, while larger, high-draw appliances require 15 amps or more.
- Watts: Watts measure the total electrical power consumed by an appliance. You can calculate wattage by multiplying volts by amps. For example, an infrared sauna drawing 10 amps on a 240-volt line consumes 2400 watts.
- Dedicated Circuits: A dedicated circuit runs directly from your main switchboard to a single electrical socket. No other appliances or lights share this line. This configuration prevents overloads that can trip your safety switches when multiple appliances run simultaneously.
- Hardwired Connections: A hardwired connection joins an appliance directly to your home electrical wiring without using a traditional plug and wall socket. Heavy-duty saunas designed for multiple occupants can require this permanent installation.
Knowing these specifications allows you to determine whether your desired sauna is a simple plug-and-play unit or if it requires dedicated electrical work before delivery.
Can an Infrared Sauna Use a Standard Household Outlet?
Smaller infrared saunas can use a standard 10-amp household outlet. However, larger models draw more power and require a 15-amp power point.
A standard 10-amp wall socket is physically different from a 15-amp socket. A 15-amp plug features a wider earth pin for safety, meaning it cannot be physically inserted into a standard 10-amp wall outlet. You must never modify a 15-amp plug or use an adaptor to force it into a 10-amp socket, as this violates Australian safety standards and poses a serious electrical fire hazard.
Do Infrared Saunas Need a Dedicated Circuit?
Most residential infrared saunas require a dedicated circuit back to your main electrical board. Even if a smaller model runs on a standard 10-amp plug, sharing that electrical circuit with other high-use appliances (such as a kettle, vacuum cleaner, or heater) can overload the circuit and trip your safety switches.
For all 15-amp and 20-amp models, a dedicated circuit is mandatory. This ensures that the sauna receives a consistent, safe flow of power, allowing the patented infrared heating heaters to perform at their designed capacity without interruption.
When a Licensed Electrician is Required
You must engage a licensed electrician if your chosen sauna requires a 15-amp or 20-amp outlet, a dedicated circuit, or a hardwired connection. In Australia, all electrical installation work must comply with Australian Standard AS/NZS 3000, known as the Wiring Rules, and local regulations.
Engaging a licensed professional is essential for several reasons:
- Safety and Compliance: Electricians ensure your wiring and switchboard can handle the continuous electrical load of a sauna.
- Warranty Protection: DIY electrical work is illegal and immediately voids your product warranty.
- Insurance Validity: Unlicensed electrical work can invalidate your home insurance policy in the event of an electrical incident.
An electrician will also inspect your switchboard to confirm it has modern safety switches, known as Residual Current Devices (RCDs), which are mandatory under Australian law for all power and lighting circuits.
Model Requirements and Technical Specifications
Each of our saunas is engineered to deliver precise infrared wavelengths, resulting in varying power requirements across the range.
| Model | Capacity | Voltage | Wattage | Amperage | Connection Type |
| Solo System | 1-Person | 240V | 960W | 4.0A | Standard 10A plug-and-play |
| Signature 1 | 1-Person | 240V | 1673W | 6.97A | Dedicated 10A circuit and socket |
| mPulse Aspire | 1-Person | 240V | 1800W | 10.0A | Dedicated 10A circuit and socket |
| Amplify II | 2-Person | 240V | 2231W | 11.0A | Dedicated 15A circuit and socket (15A plug) |
| mPulse Believe | 2-Person | 240V | 2400W | 15.0A | Dedicated 15A circuit and socket |
| Amplify III | 3-Person | 240V | 2371W | 15.0A | Dedicated 15A circuit and socket (15A plug) |
| mPulse Conquer | 3-Person | 240V | 3300W | 15.0A | Dedicated 15A circuit, 15A socket, 20A breaker |
| Amplify IV | 4-Person | 240V | 3900W | 20.0A | Hardwired connection to isolation switch |
| mPulse Discover | 4-Person | 240V | 4200W | 20.0A | Hardwired to 25A supply, 25A breaker |
| mPulse Empower | 5-Person | 240V | 4200W | 20.0A | Hardwired to 25A supply, 25A breaker |
Practical Installation Insights and Scenarios
To help you see how these requirements translate to a typical home, consider three common installation scenarios.
Scenario A: Plug and Play in a Home Gym
A homeowner decides to install a Solo System or an mPulse Aspire in a spare room. Since the Solo System only draws 4 amps and uses a standard 10-amp outlet, it can plug directly into an existing wall socket without requiring electrical modifications. For the mPulse Aspire, which draws 10 amps, the homeowner uses an existing power point but ensures that no other major appliances run on that same circuit, avoiding any unexpected power trips.
Scenario B: Upgrading for a Family-Sized mPulse Conquer
A family purchases the 3-person mPulse Conquer to place on their covered deck. Because this model requires a 15-amp power point and a 20-amp circuit breaker, they hire a licensed electrician. The electrician runs a new, heavier-gauge cable directly from the main switchboard to the deck, installs a dedicated 15-amp weather-proof outlet, and upgrades the circuit breaker in the meter box.
Scenario C: Switchboard Safety Upgrades for Older Properties
A customer buys a Signature 2 for an older terrace house built in the 1970s. During the pre-installation check, the electrician notices that the switchboard still utilises old ceramic fuses and lacks modern safety switches. Before installing the dedicated 15-amp circuit, the electrician upgrades the switchboard to include modern RCD safety switches to comply with standard AS/NZS 3000, ensuring the home can safely support the continuous electrical demand.
What to Check Before Ordering Your Sauna
To prevent any surprises on delivery day, we recommend completing this physical and environmental checklist before finalising your order.
- Physical Dimensions and Delivery Path: Measure the height and width of all doorways, hallways, stairwells, and tight corners between your delivery entrance and the final installation spot. Our saunas are delivered as flat, pre-fabricated panels, and they must fit through these pathways.
- Floor Levelness and Material: The sauna must sit on a completely flat, level surface. Suitable flooring options include tile, concrete, timber, or laminate. Avoid placing the sauna on thick, uneven carpet, which can affect the alignment of the seals or interlocking brackets.
- Power Cord Proximity: Ensure a suitable wall socket is located within 2 metres of the sauna's final position. The 2-metre power cord exits from the back left of the sauna base, and you must never use extension cords or power boards.
- Environmental Ventilation: Our saunas are designed for dry, indoor environments. If you intend to place your sauna in an outdoor space, it must be located under a fully covered, waterproof roof and protected by an outdoor cover to keep your warranty valid.
Preparing Your Space for Delivery Day
Once you have verified your electrical and physical requirements, preparing your space for delivery is simple. Clear the assembly area of any furniture or decorative items, ensuring the installation team has ample space to work.
Our saunas are designed with convenience in mind. They feature pre-fabricated panels that lock together using our patented Magne-Seal™ technology, part of a quadruple reinforcement system to keep your sauna extremely sturdy, yet pliable to adapt to the wood’s expansion and contraction over time. Having your dedicated power outlet installed and fully tested by a licensed electrician prior to delivery means you can plug in, power on, and begin your first session.
Consulting a Specialist Before You Buy
Verifying your home's electrical capacity before making a purchase ensures a smooth, worry-free installation process. You can download information on electrical certification to share with your electrician, by reviewing our comprehensive product specification sheets and installation manuals for exact dimensions.
If you have further questions or want to verify whether a specific model fits your existing home setup, we recommend reading our frequently asked questions. For personalised assistance, please reach out to our specialists to confirm suitability before purchasing.